Xmtg-2000 Temperature Controller Manual Pdf Now
85–264 VAC, 50/60 Hz (standard); select models support 24 VDC. Input Types (Configurable): Thermocouples: K, J, E, S, T, B RTDs: Pt100, Cu50
Set to 'ON' to automatically tune the PID settings to your system. 5. Troubleshooting (XMT-2000 Series) Probable Cause Display shows "EEE" Sensor disconnected or wrong type Check thermocouple wiring (Terminals 7-8). Temp doesn't rise No output, SSR/Relay broken Check output wiring; verify 12V output on SSR pins. Temp overshoots/undershoots PID settings not tuned Run the Autotuning (At) function. Controller turns on/off fast Hysteresis (HY) too low Increase HY value (if in ON/OFF mode). 6. Where to Find XMTG-2000 Manual PDF
To avoid needing to search for the again, follow this checklist once you locate it:
To configure the controller, follow these common programming steps: Setting the Target Temperature (SV) Press the key once briefly. The SV display will flash.
Operating the XMTG-2000 series involves understanding its display, buttons, and menu structure. A typical controller will have four keys: , ▲ (UP) , ▼ (DOWN) , and sometimes a shift key . xmtg-2000 temperature controller manual pdf
A: This is a hidden function. Enter Level 2 parameters (press and hold SET for 8 seconds). Find PASS code, enter 115 (the universal reset code listed in the manual). Then navigate to RST and set it to 1 .
Up to two configurable relay alarms (1A/250VAC). Terminal Wiring Diagram and Connections
Many users upload scanned copies to industrial forums.
This public link is valid for 7 days and shares a thread, including any personal information you added. This link or copies made by others cannot be deleted. If you share with third parties, their policies apply. Can’t copy the link right now. Try again later. 85–264 VAC, 50/60 Hz (standard); select models support
Enter the advanced parameter menu by holding for 3 seconds.
What you are using (e.g., K-type thermocouple, Pt100 RTD). What heating or cooling device you are controlling.
If you tell me the of your specific XMTG-2000 or the sensor type you are using, I can provide the exact wiring codes or parameter steps you need.
Used only in basic On/Off control mode to prevent rapid cycling. How to Run the PID Auto-Tuning Function Controller turns on/off fast Hysteresis (HY) too low
Offset value to correct discrepancies between sensor readout and true temperature. Parameter Lock
| Digit | Position | Description | Example Values | | ----- | -------- | ------------------------------------------------------------ | -------------------------------------------------- | | 1-2 | Fixed | "XM" stands for Digital Display & Control | XM | | 3 | Series | Indicates the series: T = Regulator, Z = Display Only | T, Z | | 4 | Size | Denotes the housing size: G = 48x48mm | G | | 5-6 | Sub-type | Represents the specific function or configuration | 2000, 2001, 2002, etc. | | 7-8 | Options | Specifies output, alarm, and input type | 1, 2, 3... (varies) |
This is the primary setting for your desired temperature.