Use the rear plate of the enclosure as a template to mark drill locations for the wall anchors.
Press and hold down the # key (or the reset button located on the back PCB, depending on production batch). the device while continuing to hold the key. Release the key after hearing a series of short beeps.
Proper installation requires understanding the terminal block connections on the back of the V2000-C unit. Before wiring, always disconnect the 12V DC power supply to prevent short circuits. Terminal Definitions Positive power input (12V DC) GND (Black): Negative power input / Ground reference PUSH (Yellow): Low-level trigger input for exit buttons OPEN (Green): High-level trigger or door switch loop
Drill a center hole through the mounting surface to cleanly route the connection cable harness. V2000-c Rfid Access Control User Manual
The V2000-C system is designed to be easy to use, with a simple and intuitive interface that allows administrators to manage access control with ease. The system can be operated using a variety of methods, including:
All commands must be entered via the keypad, followed by the # key unless noted.
Adjust how long the door remains unlocked after a valid credential swipe. Enter Programming Mode. Press 4 . Use the rear plate of the enclosure as
Sounds if the door remains open longer than the preset relay time. Reset to Factory Default Settings
Sounds if the door is opened without a valid card or exit button trigger.
Verify the input voltage is a steady 12V DC. Release the key after hearing a series of short beeps
The relay strike time dictates how long the lock stays unlocked after a valid credential swipe. Enter Programming Mode. Press 4 . Enter a value from 0 to 99 (seconds). Press # . Factory Reset Procedure
: Door Status Sensor (D_SEN) – Connects to magnetic door contact
To enter programming mode, you must use the . The default master code is usually 990101 or 123456 . Enter/Exit Programming Mode Press * + [Master Code] + # . (The LED will turn red/flash). Press * to exit programming mode at any time. Change the Master Code